Ega Master 57506 Manual De Instrucciones página 8

Separador de bridas hidráulico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Open the external drain valve to remove the wedge
a) The piston does not advance:
- Close the external drain valve completely.
- Check the oil level.
b) There is no pressure in the system:
- Check for leaks or if the connections are tighted perfectly.
c) The piston does not go backwards or it does not go backwards completely.
- Open the external drain valve.
- Check the level oil. Remove oil if there is a lot inside the system.
8
SOLUTION TO POSSIBLE MALFUNCTION

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

57507

Tabla de contenido