System Programming
Notes:
1. Reconnect the negative battery terminal prior to programming.
2. EVS I System installation requires 2 working factory RKE keyfobs for
programming options & Driver's Door Priority Unlock feature to be
enabled for proper operation of the security system. Refer to vehicle's
Service Manual.
3. This system has 2 option banks. Bank 1 has 8 options, and Bank 2
has 4 options. Refer to the Option Bank Chart on page 12 for details.
Option Programming
The remote security system has several installer programmable options which
can be changed to accomodate different circumstances. In most cases, there
will be a need to change option settings (i.e. adjustment of shock sensor
sensitivity, horn pulse output duration, etc).
A. Open the driver's door.
B. Turn the ignition to the "on" position.
C. Press and hold the programming/override button; After 10 seconds the
parking lights will flash 3 times indicating the system is now in learn
mode.
D. Release the programming button.
E. Press and release the programming button once more; The parking
lights will flash 4 times indicating the system has entered Option Bank 1.
To change the setting of an option: (EVS I Systems only)
A. Press the door trim "Lock" switch or, if the vehicle's door lock feature is
non-functional with the ignition turned on, press the factory keyfob
"Lock" button (of the keyfob that is not in the ignition cylinder) to advance
to the desired option (refer to the Option Bank Chart).
The parking lights will flash a number of times indicating which option
is selected (i.e. Two flashes indicates that option number two has been
selected).
B. Press the door trim "Unlock" switch to change the setting of an option..
The status LED indicates the setting of the option; LED ON indicates
that the option is on, LED OFF indicates that the option is off.
C. To advance to Option Bank 2, at any point while in Option Bank 1, press
and release the programming/override button to advance to option bank
number two. The parking lights will flash 5 times indicating the system
has entered Option Bank 2.
To return back to Option Bank 1, press and release the programming/
override button once again (4 flashes).
10