5. EXTRA POSSIBILITIES WITH YOUR DOORGUARD300
a. Connecting an electric door opener
- To open the door from the monitor (figure 8).
- You need an electric door opener with its own power supply. The door-open-contact of the monitor
is a potential-free normally-open (NO) contact.
- The maximum load for this contact is: DC24V/1A or AC24V/1A.
- You need to connect the door opener onto the L+ en L- connectors of the monitor, using the
supplied cable.
outdoor station
door opener
adaptor
b. Connecting multiple monitors
- To be able to see who is at the door from several places (max. 4). Upon that, you now have an
intercom system (figure 9). Available separately:
DoorGuard300
DoorGuard100
- Beware: Only the last monitor that you connect
should be switched on 75 Ohm.
- The remaining monitors are to be connected
parallel. The DoorGuard300 monitor is provided
with an extra connector for the connection of an
extra monitor.
- If you want to bridge a greater distance, then
check out the following table for the required
cable type.
Cable length
1-25m
25-50m
50-100m
100-300m
c. Marmitek Camera corner bracket
To be able to mount your DoorGuard300 camera in the corner of the door frame. Art.no: 09746
6
12:05
Pagina 6
indoormonitor
figure 8
door opener
Black/white Hands Free monitor:
Black/white monitor:
Required cable type
4 core cable of minimum 4x 0,55mm
coax cable, 75 ohm of minimum 0,5mm
coax cable, 75 ohm of minimum 1.0mm
coax cable, 75 ohm of minimum 1.5mm
Terminals function:
Brown (R1)
Black
White (R3)
Red
L+ : dooropener
L- : dooropener
adaptor
art.no: 09786 (E version) 09787 (UK version).
art.no: 09692 (E version) 09693 (UK version).
Figure 9.
door opener
2
+ 2 wire audio 0,35mm
2
+ 2 wire audio 0,35mm
2
+ 2 wire audio 0,5mm
2
: VIDEO
(R2)
: GNO
: AUDIO
(R4)
: VCC
2
2
2