Thermometer
Heater SH
Heater R
Type
Volume
Rated pressure
Weight / Filled with water
Anti-corrosion protection of tank
HE heated surface - lowe
HE heated surface - upper
HE volume - lower
HE volume - upper
insulation thickness
Degree of protection
HE - Heat exchanger
On the rear side of the hot water tank there are special channels (H1, H2) for mounting the
feelers for regulation of the system connection of the hot water tank to other heating sources.
Access to the channels is under the covering joint of the protective covering, approximately
in the middle of the tank height.
Insert the feeler into the channel and fix it with the enclosed rubber tap. Recommended
position (h1, h2) of the feeler is marked on the drawing:
- If the feeler is mounted higher than recommended, the thermostat will react too fast,
the operating time of the circular pump will be shorter and the difference between the
temperature in the hot water tank and heating media after the thermostat switch off will be
higher. This means that the quantity of water in the hot water tank and its temperature will
be lower,
- If the feeler is mounted lower than recommended, the operating time of the circular pump
will be longer and the difference between the temperature in the hot water tank and
heating media after the thermostat switch off will be lower. This means that the quantity of
water in the hot water tank and its temperature will be little higher.
KGV 200-1
[l]
200
[MPa ]
[kg]
82 / 282
2
[m ]
1,05
2
[m ]
-
6,6
[l]
[l]
-
[mm]
KGV 300-1
KGV 300-2
285
0,6
112 / 397
134 / 414
Enameled/Mg Anode
1,6
-
10
-
57
IP 21
280
1,6
1,09
10
6,8