Danby DAS120EAQHWDB Manual Del Propietário página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
EXTENDING THE PIPES
When extending the rolled pipes, straighten them by
unwinding gently as shown. Do not pull from either
end as this can cause the pipe to bend or twist.
If the pipes are bent or pulled two often, they will
become weak and can leak. Do not bend the pipes
any more than three times in any one spot.
Do not remove the cap from the pipes until making
the connections to avoid dirt or debris entering the
pipes.
CONNECTING THE INDOOR UNIT
1. Remove the cap from the pipe attached to the
indoor unit.
2. Align the female quick connector to the male
end and attach.
3. Hold the short position (A) of the male quick
connector by open-end spanner and do not
turn. Use a torque wrench to hold the short
position (B) of the female quick connector which
is attached with a long copper pipe and quickly
turn to tighten them. Follow the proper torque
chart.
4. To protect the quick connector and ensure
effi cient performance, cover the quick connector
with a foam pad.
YES
7
NO

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Das180eaqhwdb

Tabla de contenido