ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead con-
nected to the battery's positive
pole?
2. Is the charger connected to a 12V
battery?
3. Has charging been interrupted in
STEP 1, 2 or 5?
Restart the charger by pressing the MODE-
button. If charging is still being interrupted, the
battery...
STEP 1: ...is seriously sulfated and may need
to be replaced.
STEP 2: ...can not accept charge and may
need to be replaced.
STEP 5: ...can not keep charge and may need
to be replaced..
50013552C MXS 5.0 NA, Manual, Print file 002.indd 11
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT
The charger has entered the energy save mode.
This happens if the charger isn't connected to a
battery in 2 minutes.
MAINTENANCE
INSTRUCTIONS
The MXS 5.0 (1090) is maintenance-free. The charger must
not be opened; doing so will invalidate the warranty. If the
power cable is damaged the charger must be returned to the
retailer. The charger casing can be cleaned using a damp
cloth and mild cleaning agent. Remove the plug from the
power socket before cleaning.