7. Installation and use of the TIG process
1. Turn on the machine.
2. Select the current according to the filler diameter to be melted.
3. Cable connection: The TIG torch must be connected to the connector with negative
polarity and the work clamp with positive polarity.
4. Connect the torch trigger cable and the torch gas fitting to the front of the machine.
GAS installation
www.ELITETOOLS.co
In
TIG
the
gas
connected to the rear inlet of
the
equipment,
connected to the front gas
outlet of the equipment and the
torch
trigger
connected in the respective
socket. The arc start is given by
HF start or lift start. The gas
used must be Argon or Helium,
the
cylinder
must
pressure regulator and a gas
flow of 6 to 10 l/min or 13 to 21
CFH is recommended
Keep Working
must
be
the
torch
connector
have
a
23