SAFETY INFORMATION
WARNING
• DO NOT work on pump until power is disconnected.
• DO NOT cut off ground pin or use an adapter fitting.
• DO NOT use an extension cord.
• The pump power cord should be connected to a separately fused, grounded line with a minimum
capacity of 15 amps. It can be connected to a non fused breaker at the recommended amperes.
• ELECTRICAL PRECAUTIONS – Before servicing a pump, always shut off the main power breaker
and then unplug the pump. Make sure you are not standing in water and are wearing insulated
protective sole shoes, under flooded conditions. Contact your local electric company or a qualified
licensed electrician for disconnecting electrical service prior to pump removal.
• Sump basin must be vented in accordance with local plumbing codes. This sump pump is not
designed for and CANNOT be installed in locations classified as hazardous.
• The following may cause severe damage to pump and will void the warranty.
– Using an extension cord.
– Cutting off the ground pin or using an adapter fitting.
– Working on pump or switch while plugged in.
– Removing motor housing, unscrewing impeller, or otherwise removing impeller seal.
– Running the pump continuously.
– Pumping chemicals or corrosive liquids.
– Pumping gasoline or other flammable liquids.
– Plastic PVC pipe can be installed in the outlet piping. Drain hose, galvanized steel or copper pipe
may be used if desired. All piping must be clean and free of all foreign matter to prevent clogging.
– Pump will be inadequate if suspension liquids contain solid particles larger than 3/8 in.
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package
contents list. If any part is missing or damaged, do not attempt to assemble the product.
Estimated Assembly Time: 15 minutes
Hardware Required for Assembly (not included): Sump basin, inlet piping, discharge piping (PVC,
polypipe, or galvanized steel), check valve, and PVC glue.
• Before installing or servicing this pump, be certain power source is disconnected.
• Installation and electrical wiring must adhere to state and local codes and must be completed
before priming pump. Check appropriate community agencies or contact local electrical and pump
professionals.
• Call an electrician when in doubt. Pump should be connected to a separate 15 amp circuit breaker
or 15 amp fuse block. Note that plugging into existing outlets may cause low voltage at motor. This
could cause blown fuses, tripping of motor overload or burned-out motor.
3
Lowes.com