14) Install the rear access cover with the vent tube coming
out the upper left bushing, the 20' discharge tube coming
out the upper right bushing, and the service power cord out
the lower bushing. (See Figure 8). Fasten the vent tube to
the rear of the ice machine with the screws and "P" clamps
provided in the drain pump kit. Fasten the access cover
to the back of the ice machine with the screws removed in
step 6.
15) Run the 20' drain tubing to a suitable drain. The maxi-
mum lift of the drain pump is 8 feet (2.4 meters).
When finished with the drain pump installation the ice ma-
chine can be returned to service. Refer to your ice machine
owners guide for turning the ice machine "ON". Be sure the
water to the ice machine is turned on.
DRAIN PUMP INSTALLATION