5) Unfasten the drain pump ground wire connection, see
Figure 10, and remove the drain pump from the ice ma-
chine, (See Figure 10).
6) Disconnect the electrical plug connection from the side
of the drain pump, see Figure 11.
7)Disconnect the cabinet power cord from the drain pump.
(See Figure 11).
8) Reverse this procedure to assemble the new drain
pump into the cabinet and re-install the leveling leg to its
original position..
NOTE
The vent tube must be attached and secured or water
damage may occur. Make sure there are no kinks in the
tube. The drain pump will not operate correctly with a
partially blocked vent tube.
Cabinet power cord
Disconnect step 7
Press down on
rear tab and
disconnect
Figure 11a
DRAIN PUMP INSTALLATION
Drain pump
ground, secure
at rear flange of
cabinet base
Figure 11
CAUTION
!
When replacing tube clamps, do not overtighten which
could damage the tubing. Tighten screws until "snug", then
retighten several minutes later after the material relaxes, to
assure a water tight connection.
Drain pump
harness to
main electronic
board.
Disconnect step 6
9
Drain pump harness
ground, secured at
front of cabinet base