General Safety Information; Tool Components And Specifications - Campbell Hausfeld SB3232 Manual De Instrucciones

Tabla de contenido

Publicidad

Operating Instructions
General Safety
Information
(Continued)
Danger indicates
DANGER
!
an imminently haz-
ardous situation which, if not avoided,
WILL result in death or serious injury.
G Read and understand
tool labels and manual.
Failure to follow warn-
ings, dangers, and cau-
tions could result in
DEATH or SERIOUS
INJURY.
G Do not use any type
of reactive gases,
including, but not lim-
ited to, oxygen and
combustible gases, as
a power source. Use
filtered, lubricated,
regulated compressed air only. Use
of a reactive gas instead of com-
pressed air may cause the tool to
explode which will cause death or
serious personal injury.
G Use only a pressure-
regulated compressed
air source to limit the
air pressure supplied
to the tool. The regu-
lated pressure must
not exceed 100 psi. If the regulator
fails, the pressure delivered to the
tool must not exceed 200 psi. The
tool could explode which will cause
death or serious personal injury.
G Never use gasoline
or other flammable
liquids to clean the
tool. Never use the

Tool Components And Specifications

• REQUIRES: 0.8 SCFM with 10 fas-
teners per minute @ 90 psi
• AIR INLET: 1/4" NPT
• FASTENER SIZE RANGE: 1/2" to
1 1/4"
• MAGAZINE CAPACITY:
100 fasteners per load, 18 gauge
• STAPLES: 1/4" crown
• WEIGHT: 2 lbs., 10 oz.
• LENGTH: 9 1/2"
• HEIGHT: 7 1/2"
• MAXIMUM PRESSURE: 100 psi
• PRESSURE RANGE: 60 - 100 psi
www.chpower.com
tool in the presence of flammable
liquids or gases. Vapors could ignite
by a spark and cause an explosion
which will result in death or serious
personal injury.
G Always remain in
a firmly balanced
position when
using or handling
the tool.
G Do not remove,
tamper with, or
otherwise cause
the Work Contact
Element (WCE) or
trigger to become
inoperable. Do
not operate any tool which has been
modified in a like fashion. Death or
O
CO
2
serious personal injury could result.
G Do not touch the
trigger unless dri-
ving fasteners.
Never attach air
line to tool or
carry tool while
touching the trig-
ger. The tool could eject a fastener
which will result in death or serious
personal injury.
100 psi
MAX.
WARNING
!
hazardous situation which, if not avoid-
ed, COULD result in death or
serious injury.
G Always discon-
nect the tool
from the power
source when
unattended,
Work contact element (WCE)
G Always fit tool
G Never place hands or
CAMPBELL
CAMPBELL
HAUSFELD
HAUSFELD
PROFESSIONAL
PROFESSIONAL
G Never carry the
Warning indicates
a potentially
Cap exhaust
Trigger
Fastener discharge area
2
Model SB3232
performing any maintenance or
repair, clearing a jam, or moving the
tool to a new location. Always
reconnect the air line BEFORE load-
ing any fasteners. Do not load the
tool with fasteners when either the
trigger is depressed or the Work
Contact Element (WCE) is engaged.
The tool could eject a fastener caus-
ing death or serious personal injury.
with a fitting
or hose cou-
pling on or
near the tool in
such a manner
that all com-
pressed air in the tool is discharged
at the time the fitting or hose cou-
pling is disconnected. Do not use a
check valve or any other fitting which
allows air to remain in the tool. Death
or serious personal injury could occur.
any other body parts in
the fastener discharge
area of the tool. The
tool might eject a fas-
tener and could result
in death or serious personal injury.
tool by the air
hose or pull the
hose to move the
tool or a compres-
sor. Keep hoses
away from heat,
oil and sharp edges. Replace any
hose that is damaged, weak or
worn. Personal injury or tool dam-
age could occur.
Warning label
Latch button
Magazine

Publicidad

Tabla de contenido
loading

Tabla de contenido