ERROR AND TROUBLESHOOTING

If pump failure occurs, the error code will appear on the display.
Error code
E1x 
Load errors 
E10 (drY)
Low motor load
E11
High motor load
E2x 
Protection active 
E22 (hot)
Converter temperature limit
Converter
E23
protection
E24
Converter overcurrent
E25
Overvoltage
E26
Undervoltage
E27
PFC Overcurrent
E3x 
Pump errors 
Software motor protection
E31
active.
E4x 
Device specific error codes 
General frequency converter
E40
error
E42 (LEd)
LED faulty
E43 (con)
Communications failed
E44
DC link current offset
Motor temperature outside
E45
limits
Circuit temperature outside
E46
limits
Voltage
E47
limits.
E48
15V outside limits
E49
Test SW
E5x 
Motor error codes 
Motor parameters out of
E51
range
E52
Thermal protection active
E53
Invalid model selected
Pump is non-responsive
Pump doesn't work
Description
Low load detected. Pump is running dry.
Motor might be faulty or viscous medium is present.
Circuit is too hot and power was reduced to less than 2/3 of rated
power.
temperature
Circuit is too hot to run, pump stopped
Hardware overcurrent protection triggered.
Line voltage is too high
Line voltage is too low for proper operation.
Power correction circuit current cannot be controlled
Average motor current was too high, pump load is much higher
than expected
Electrical circuitry did not pass self-test.
One of the display segment diodes is faulty (open/short)
Display board does not detect proper connection to main board,
but power supply is present
Voltage on DC link shunt (R34) not in expected range
During MFG. TEST, this is 10 kΩ, 1% resistor for 10 °C..30 °C During
operation, expected values are -55 °C..150 °C
During MFG. TEST, this is 0 °C..50 °C. During operation, expected
values are -55 °C..150 °C
reference
outside
Comparison between internal references does not match
15V power supply is not 15V.
Pump has to be reprogramed.
 
Motor does not behave as expected
Motor temperature is too hot to operate.
Pump model not valid or out of reach.
Turn power on and off.
Check electrical installation and fuse.
Probable cause
38