Festo AS-Interface ASI−EVA−2E2A−M12− 8POL−Z Manual Del Usuario página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Type
Load voltage connection (only if
configured with DIL switch)
Rated value (protected against
incorrect polarity)
Residual ripple
Maximum current consumption
(sum of currents, at 24 V)
Outputs (valve connection)
Voltage range
Max. current consumption
Without additional supply
With additional supply
1)
Digital inputs
Max. current consumption
Per input
Sum currents (all inputs)
Input current high/low
Logic level
Reference potential
Response delay
1)
The techn. specific. of the inputs and outputs have been adapted to
match the valve−cylinder combination type DNCV−... from Festo.
26
ASI−EVA ...
21.6 ... 26.4 V DC
4 Vpp
0.5 A (0.25 A per output)
1)
Watchdog function active
after 50 ms (see 3.4)
Approx. 1.4 V under load or
AS−Interface voltage
2 * 1 W−coil
0.5 A (0.25 A per output)
2 inputs in accordance with
IEC 1131−2 type 2, 24 V DC,
PNP, status display LED
Without
additional
supply
100 mA
100 mA
6 mA / 2 mA at 5 V
(2−wire sensor)
ON: 11.5 ... 30 V
OFF: − 30 ... 5 V
0 V
Typ. 3 ms (at 24 V)
Festo ASI−EVA−2E2A−M12−8POL−Z 0212NH English
With
additional
supply
200 mA
200 mA

Publicidad

Tabla de contenido
loading

Tabla de contenido