USER GUIDE
RF basic thermostat WFHTRF 01 (20033)
MODES DESCRIPTION
- Radio frequency RF thermostat (433.92 Mhz) specially designed for water floor
heating.
- Personal code on each product.
- Equipped with a switch to select 3 different operating modes:
-
Comfort (The thermostat follow the setting temperature)
- Off
-
Night reduction (The thermostat follow the setting temperature – 4°C)
- To be used only with ours receivers.
LED Indicator.
Batteries
GB
RADIO CONFIGURATION MODE
- Turn the thermostat in Off position.
- To assign (*) the RF thermostat with the receiver you must put the
receiver in "RF init" mode (please refer to the receiver leaflet).
- After you have just made the thermostat in
The thermostat sends its configuration address by radio signal. (The
thermostat LED blinks green)
* (In this mode the thermostat should be near the receiver)
LED INDICATOR
Red:
Red Blinking:
Green blinking:
TECHNICAL CHARACTERISTICS
Measured temperature
precision
Operating temperature
Select
mode.
Setting temperature range
Regulation
characteristics
Room
Electrical Protection
setting.
Power Supply
Battery operated life
Radio frequency
certifications
Soft version
or
mode.
- Heating indication (During consign adjustment)
- 1 second cycle => Low batteries indication.
- Radio transmission (1 flash by transmission)
0.1°C (or 0.2°F)
0°C - 50°C (or 32°F – 122°F)
5°C – 30°C (or 41°F - 86°F)
Proportional band 15min for 2°K
Class II - IP30
2 x 3V (CR2430)
~ 2 years
433.92 MHz, <10mW.
CE. EN 301489-1, EN 300220-1
(Radio frequency certifications)
V 2.0x
PPL IMP 1134A