USER GUIDE
Chrono-Thermostat MILUX RF
CHARACTERISTICS
• Wireless communication by radio signal to
the receiver connected to the
installation.
Range of approximately 30m in
residential environment.
• 7 day program
• 9 Built-in programs and 4 User programs
• Program graphic display
• Room temperature and time display
• Comfort / Reduced / Anti-freeze
temperatures
• Temporary temperature override
DISPLAY
3
2
1
1:
Heater in operation
2:
Temperature overridden
10
3:
Holiday function activated
4:
Operating mode menu
9
5:
Batteries weak
6:
Day of the week
7:
Time
8:
Current day graphic program display
and radio transmission activity
9:
If lit-up 10 display the current room temperature
10: Room temperature or set temperature
MODES DESCRIPTION
Use
&
keys to change the mode in the Operating mode menu
For all operating modes the receiver switch should be placed on AUTO position.
Set CLOCK Menu :
Use this menu to adjust the clock .
Use
&
to
ajust the minutes.
Press
key
Use
&
Adjust the hours.
Press
key
Use
&
Adjust the day
Press
key
COMFORT operating mode :
By pressing
&
keys the comfort
temperature starts to blink and can be adjusted.
The room temperature
reappears after a few
seconds
The MILUX RF regulation will now follow
indefinitely the comfort temperature.
AUTOMATIC operating mode:
MILUX RF will follow automatically the program
according to the actual time
By pressing
&
key you can override the
current set temperature until the next change in
the program.
The
segment will lit up. Use
&
to adjust the temporary required temperature.
At the next program change the
will
disappear and the program continues without any
alteration.
Automatic or Manual operation
Holiday function
Keypad lock function (child safety)
Battery operated, life >2 years
Battery weakness display
Battery replacement without loss of
the program memory (<1minute)
Reset function
ITCS function (optional). Intelligent
Temperature Control System.
4
8
REDUCED operating mode :
By pressing
&
keys the comfort
temperature starts to blink and can be
adjusted.
The room temperature
reappears after
a few seconds
The MILUX RF regulation will now follow
indefinitely the reduced temperature.
ANTI FREEZE operating mode:
Prevent your installation from freezing.
By pressing
&
keys the anti freeze
temperature starts to blink and can be
adjusted.
The room temperature
reappears after a
few seconds
Now the MILUX RF will keep the
temperature above freezing.
OFF mode :
Use this mode if your Heating installation
needs to be turned OFF.
The MILUX RF will switch off the
installation and then switch itself OFF
(blank screen).
User programs are saved, time is kept
running and battery consumption becomes
very low.
Any key will wake up the MILUX RF.
The
key display the actual room
keys
temperature.
DANGER: has your thermostat is
stopped YOUR INSTALLATION CAN
FREEZE.
GB
PROGRAM menu :
By pressing
&
&
Then use
Select the program
If you select a built-in program "P1 to P9" and press
Built-in programs description
P1 Morning, Evening & Week-end
P2 Morning, Midi, Evening & Week-end
P3 Day & Week-end
P4 Evening & Week-end
P5 Morning, Evening (bathroom)
If you select a built-in program "U1 to U4" and press
USER PROGRAM EDITION
The
key sets
The
key sets
Use
&
keys to slide the blinking cursor position in the day and modify or correct easily the
program. When the displayed day is correct press
When you press
Now your user program will be followed if you put the MILUX RF in

SPECIAL FUNCTIONS

HOLIDAY Function :
With
&
keys, go to
( H ) if below 24h then in days ( d ). Then select a mode
The
logo is active and the number of hours/days left is displayed until the MILUX RF
returns in
mode and continues to follow the program.
KEYPAD LOCK Function :
Function to prevent any modification of the parameters.
5
In
,
,
press simultaneously on the
6
keypad.
RESET Function :
7
Erase all user programs and sets the factory parameters by default.
Go to
mode, maintain
All segments will lit up during a few seconds showing that the MILUX RF has been erased and
restarted with factory defaults parameters.
Factory parameters are :
Temperatures
RADIO CONFIGURATION WITH THE RECEIVER
1.
To assign the MILUX RF thermostat with the receiver you must put the receiver in "RF init"
mode, please refer to the receiver leaflet. (In this mode the thermostat should be near the
receiver)
2.
On the MILUX RF, select
Then press the
you will enter in the Radio configuration mode (
The MILUX RF is now sending by radio signal its configuration address 4 times per second,
3.
You can now perform a radio range verification.
Place the MILUX RF in the room where you need to regulate the temperature and leave it in
Radio configuration mode (
Close the doors and come back to the Receiver.
Verify that the green LED blinks at each radio signal received :
- If it blinks regularly 4 times per second, the installation of the MILUX RF and Receiver is
correct.
- If it blinks irregularly, you are at the range limit. Install the MILUX RF closer to the Receiver.
- If it does not blink at all, you are out of range. Install the MILUX RF closer to the Receiver.
4.
On the MILUX RF press on the
Now your MILUX RF controls the Receiver.

TECHNICAL CHARACTERISTICS

Operating temperature
Measured temperature precision
Set temperature precision
Set temperature range
Regulation
characteristics
Electrical Protection
Batteries
Radio Frequency
Certifications
keys the Program number starts to blink,
to
this program will be followed in
P6 Morning, Afternoon & Week-end
P7 7h - 19h (Office)
P8 8h - 19h , Saturday (Shop)
P9 Week-end (Secondary House)
day
Hour at the cursor position
temperature at the current blinking program hour
temperature at the current blinking program hour
to jump to the following day.
on day 7 you return to the top menu
function. Then select with
,
and
operating modes you can maintain the
or
key to lock (
&
keys pressed and press simultaneously on the
21°C
17°C
6°C,
Program U1 all comfort.
operating mode.
key during 5 seconds,
).
key to exit the Radio configuration mode.
0°C - 50°C (o 32°F – 122°F)
0.1°C (or 0.2°F)
0.5°C (or 0.5°F)
in comfort & reduced : 5°C – 35°C (or 41 - 95°F)
in anti-freeze: 0,5°C – 10°C (or 33 – 50°F)
Cycle: 15 minutes
Anti-short cycle: 3 minutes OFF, 2 minutes ON
Class II - IP30
3x LR6 AA 1.5V alkaline batteries (> 2 years)
IMPORTANT: You have 1 minute to change the
batteries.Past this time, you may have to reprogram
your thermostat if all segments lit up at power up.
433.92 MHz, <10mW.
CE. EN 300220-3, EN 301489-1
(Radio frequency certifications)
and use
&
to see the
other days in the program
Shows the daily program
you will enter in user program edition.
operating mode.
&
keys the delay in hours
or
or
.
key pressed and
) or unlock (
) the
key.
).