Festo Compact performance CPA ASI−8E8A−Z Manual Del Usuario página 24

Terminal de válvulas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
3.5 Address assignment of the valve solenoid coils
Addresses are assigned to the valve solenoid coils of both
slaves in ascending order without gaps, from left to right.
Depending on the manifold block, a valve location
occupies one address (CPA..−EV1) or two addresses
(CPA..−EV2). If a manifold block occupies 2 addresses, the
following applies:
pilot solenoid 14 lower−value address,
pilot solenoid 12 higher−value address.
Examples: Fitting equipment in the valve locations
4 double−solenoid valves
(manifold block EV2)
1 2
1 3
0 2 4
5 7
1
Output addresses of slave 1 (O0...O3)
2
Output addresses of slave 2 (O4...O7)
24
6
2 double−solenoid valves (EV2),
4 single−solenoid valves (EV1)
1
2
1
0
2 3 4
5
Festo CPA..−ASI−8E8A−Z 0303NH English
6
7

Publicidad