Electric Diagram - Truper BOAP-1/2 Manual De Instrucciones

Ocultar thumbs Ver también para BOAP-1/2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
The motor does not start.
The motor runs without
pumping water.
Flow speed is not enough.
The motor overload short
is activated
Failure to follow with these caution advices may damage the pump and void the warranty.
CONCRETE BASE
SUCTION PIPING
RIGHT INSTALLATION
CAUSE
- There is no energy.
- Blocked impeller.
- Clogged lter.
- Excessive height in the suction.
- Air in the admission.
- Suction height is in the limit.
- Filter is partially clogged.
- Blocked impeller.
- Motor overload.
- Stuck impeller.
JOINER NUT
SUPPORT
MINIMUM LEVEL
19.6"
FOOT VALVE
SAND BOX
SOLUTIONS
- Check the connections and the power values
- See the maintenance section
- Clean the lter
- Reduce the suction pipe length.
- Double-check the suction pipe is hermetic.
- Check the foot valve is submerged at least 19.6"
- Priming the pump back is required.
- Verify the suction height.
- Shorten the suction pipe length.
- Clean the foot valve and the whole suction pipe is necessary.
- Disassemble the pump and carefully clean the pump body and
the impeller.
- Double-check power and ventilation.
- Release the impeller ( see the maintenance section)
INSTALLATION
WRONG INSTALLATION

ELECTRIC DIAGRAM

R
REGULATE VALVE
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Boap-3/4Boap-1100681006910070

Tabla de contenido