TECHNICAL DATA:

Voltage:
Frequency:
Rotation Frequency:
Thermal insulation on motor winding: F
MODEL
POWER
BOAP-1/2
1/2 Hp
BOAP-3/4
3/4 Hp
BOAP-1
1 Hp
IMPORTANT NOTICE: To avoid risk of electrical shock or serious accident, if power cord gets damaged it should be repaired by the manufacturer
or by Truper® Authorized Service Center.
Power cord grips used in this product: Type"Y".
Assembly design in this product causes insulation to be affected by liquid spills or splashing
WARNING
Before gaining access to terminals, all power circuits should be disconnected.
USE
Agricultural applications in irrigation systems for mini-spraying or area spraying where the pressure requirements are larger due to the height
of the irrigation system and the minimum pressure required for the correct functioning of spraying or nebulization. In this type of applications
the use of centrifugal pumps is not recommended due to the low output pressure they handle.
Dish Sprayera
GENERAL SAFETY GUIDELINES
Read and understand all the instructions. Failure to follow all the following instructions may result in electric shock,
WARNING
re and/or severe personal injury.
Carefully follow the following instructions to gain the best performance and a long duty cycle of the pump.
In the event of any problem please contact your Truper Authorized Service Center.

OPERATION CONDITIONS

These pumps have been designed to pump neutral and clear liquids with no suspended abrasive solids; under temperatures no higher
than 104 ºF Adequate for vegetable farms irrigation. Pumping non-aggressive liquids and to increase low pressure in the aqueduct
network.
SET UP
The pumps shall be set up in a dry place, adequate ventilation and temperature not exceeding 104 ºF
(Fig. A). Set the pump in place on a solid at surface using the adequate bolts to prevent from vibration.
The pump shall be set up in a horizontal position to allow the bearings to work properly. The suction
pipe diameter shall not be smaller than the suction inlet. If the suction height exceeds 157.4" use a
pipe with a large diameter. The output pipe diameter should be chosen to resist the ow speed and
required pressure in the force points. The suction pipe shall be set up with and upward angle facing
Power cord grips: Type Y
120 V~
Build quality: Basic insulation.
60 Hz
Insulation quality: Class I
3 450 RPM
Duty Cycle: 50 minutes work per 20 minutes idle.
Maximum 6 hours per day.
MAXIMUM
CURRENT
HEIGHT
5 A
131.2 ft
7,6 A
213.2 ft
11 A
229.6 ft
Overhead Irrigation System
the suction inlet to prevent air pockets. (Fig. B). Double-check
the suction pipe is completely hermetic and to be submerged
in water at least one meter to prevent air bubbles. It is advisable
Fig. B
to install a check valve between the output and the speed
adjusting ow gate to prevent a dangerous water column that
exceeds 65.6 ft
MAXIMUM
MAXIMUM TOTAL
MANOMETRIC
SUCTION DEPTH
HEIGHT
26.2 ft
131.2 ft
26.2 ft
213.2 ft
26.2 ft
229.6 ft
INPUT
TYPE OF
DIAMETER
CONDUCTOR
1 NPT
18 AWG
1 NPT
18 AWG
1 NPT
16 AWG
Irrigation Sprayer
Fig. A
104 ºF
maximum
2