Electrical Connections; Technical Data; Troubleshooting - DITEC ENTREMATIC PASS24 Manual De Instalación

Sensor de microondas
Ocultar thumbs Ver también para ENTREMATIC PASS24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
DECLARATION OF CONFORMITY
EN
Manufacturer:
DITEC S.p.A.
via Mons. Banfi, 3
21042 Caronno Pertusella (VA) - ITALY.
Herewith declares that the microwave sensor PASS24 is in conformity with
the provisions of the following EC directives:
- R&TTE Directive 1999/5/EC
- EMC Directive 2004/108/EC
- Low Voltage Directive 2006/95/EC.
Caronno Pertusella, 15-03-2010
GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally competent personnel
only.
Read the instructions carefully before beginning to install the product. Incor-
rect installation may be a source of danger.
Packaging materials (plastic, polystyrene, etc.) must not be allowed to litter
the environment and must be kept out of the reach of children for whom they
may be a source of danger.
Before beginning the installation check that the product is in perfect condi-
tion.
For repairs or replacements of product only original spare parts must be
used. These instruction must be kept and forwarded to all possible future
user of the system.
To handle electronic parts, wear earthed antistatic conductive brace-
lets.

1. TECHNICAL DATA

Power supply
Absorption at rest
Absorption when detecting
Frequency
Output contact
Protection degree
Temperature
Max installation height
2. REFERENCE
[1] Cover
[2] Sensitivity adjustment trimmer
[3] Command terminal board
[4] Led / Operation indicator
[5] Sensor module
[6] Adjustment bracket
3. INSTALLATION AND FUNCTIONING
(Fig. 3) Remove the cover [1] by inserting a screwdriver in the hole on the
upper part of the sensor.
Securely fix the sensor to a flat surface using screws and plugs (not supplied)
and position it so that it can monitor the entire area opposite the passage
opening.
NOTE: avoid putting any swaying objects - such as curtains, signs or plants
- in the detection area. Ensure that rain and snow cannot fall directly onto
the sensor or it doesn't detect them, and also that it is not directed towards
fluorescent lamps.
Outside the
detection area
Stand-by
4
OFF
Led
Output
relay
N.O.
IP2064 • 2011-06-01
Silvano Angaroni
(Managing Director)
24 V=
50 mA
80 mA
24,125 GHz
30 V / 1 A max (resistive load)
IP54
from -20° C to +55°C
3 m
Inside the
Outside the
detection area
detection area
Stand-by
Motion
detection
ON
OFF

4. ELECTRICAL CONNECTIONS

Make the connections indicated in fig. 5.
WARNING: The product must be connected to an extra-low voltage power
source (SELV) which is protected from overcurrent and shortcircuiting.
5. ADJUSTING THE DETECTION AREAS
Selecting the type of detection area.
Choose the required form of the detection area, pointing the sensor module
[5] as indicated in figures 7 and 8.
(Fig.6) To select a restricted area, remove the sensor module cover, then
remove the sensor module [5] and rotate it by 90° anticlockwise before insert-
ing it in the special connection.
Selecting the depth of the detection area.
The depth can be altered by changing the vertical positioning of the adjust-
ment bracket [6]. In the examples of figures 7 and 8, the vertical angle is 30°.
NOTE: check the sensor does not detect the moving door wing.
Selecting the detection area
The position (towards the right or left) of the detection area is obtained by
rotating the adjustment bracket [6] clockwise or anticlockwise.
Adjusting the sensitivity
Adjust the sensitivity of the detection area by means of the sensitivity adjust-
ment trimmer [2], as indicated in figures 7 and 8.

6. TROUBLESHOOTING

Problem
Cause
It does not work Power supply voltage
Faulty connection
It does not
Sudden change in the de-
always work
tection area conditions
It works by itself There is a moving object in
the detection area
Presence of water drops
on the cover.
The sensor detects
rainfalls or snowfalls
The sensor is subject to
vibrations
The sensor detects the
moving door wing
All right reserved
All data and specifications have been drawn up and checked with the gre-
atest care. The manufacturer cannot however take any responsibility for
eventual errors, ommisions or incomplete data due to technical or illustrative
purposes.
4
Solution
Check the power supply
Check the wiring and the
connector
Check the installation con-
ditions
Check the direction of the
sensor and/or its sensitivity
Remove the object
Clean the cover and check the
sensor installation
Check the installation con-
ditions
Install the sensor firmly
Correctly adjust the detection
area and sensitivity with TR1.

Publicidad

Tabla de contenido
loading

Tabla de contenido