The plug must be assembled as it follows:
1. To insert a contact, push it straight into the appropriate
circuit cavity as far as it will go.
2. Pull back into the contact wire with a force of 4.45 to
8.9 N to be sure of the retention fingers are holding
the contact.
(a)
Pull back
on wire
3. After all required contacts have been inserted, the
wedge lock must be closed to its locked position.
Releasing the locking latches by squeezing them
inward.
4. Slide the wedge lock into the housing until it is flush
with the housing.

7 DISASSEMBLY PROCEDURE

The plug must be disassembled (contacts removed)
as it follows:
1. Insert a 4.8 mm wide screwdriver blade between the
mating seal and one of the red wedge lock tabs.
2. Pry open the wedge lock to the open (as shipped)
position.