KP 2600
Open jaw digit electrical tester
Note:
1. If the resistance being measured
exceeds the maximum value of the
range selected or the input is not
connected, an overrange indication
"OL"will be displayed.Set rotary
switch at desired V~ position.
Select the desired AC voltage
range, or set automatic range.
2. When checking in-circuit
resistance, be sure the circuit
under test has all power removed
and that all capacitors have been
discharged fully.
3. For measuring resistance above
1MΩ, the meter may take a few
seconds to get stable reading.
This is normal for high resistance
measurements.
4. When the input is not connected,
i.e. at open circuit, the figure
"OL" will be displayed for the
overrange condition.
Diode measurement
1. Insert the black and red test leads
into the COM and VΩHz input
terminals respectively.
2. Set rotary switch at desired
Ω position.
3. Push F.FUNC. button to select
4. The red lead should be connected
to the anode and the black lead to
the cathode of the diode.
5. The typical voltage drop should be
about 0.6V for silicon diode or 0.3V
for germanium diode.
Instructions manual |
20
6. If the diode is reverse biased or
there is an open circuit the reading
displayed will be "OL".
Continuity testing
1. Insert the black and red test leads
into the COM and VΩHz input
terminals respectively.
2. Set rotary switch at desired
Ω position.
3. Push F.FUNC. button to select
4. If continuity exists (i.e., resistance
less than 30Ω) built – in buzzer will
sound.
Capacitance measurement
1. Insert the black and red test leads
into the COM and VΩHz input
terminals respectively.
2. Turn the rotary switch to
position.
Connect test leads across the
capacitor under measurement
and be sure that the polarity of
connection is observed (Note: The
polarity of the red lead connection
is positive "+").
3. Read the measure result directly
from the display.
.
.