4.3 Input mode (time meter)

4.4 Operating mode

*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
10
Start/Stop via Inp B.
Timing while Inp B (Gate)
not active or open
Start/Stop via Inp B.
Timing while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Time Start/Stop via INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the timer
status.
Time start via INP A, stop
via INP B. (LOW-HIGH
edge with pnp; HIGH-
LOW edge with npn)
Time unit: seconds (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: minutes (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: hours (resolu-
tion depending on posi-
tion of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)

4.5 Decimal point

4.6 RESET mode (time meter 1)
4.7 RESET mode (time meter 2)
The decimal point defines
the resolution of the pro -
gram med time unit.
0
1
0.0
1/10
(0.1)
0.00
1/100 (0.01)
0.000 1/1000 (0.001)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
MN05401010E