TERM
See ATS control panel installation manual
This link connects the negative of the supply to the chassis
and earth lug. The link is not normally installed.
Operational modes
Mode dual optical fibre connections
See Figure 2.
In this mode, two separate uni-directional optical fibre cables
are used, one for transmitting and one receiving. The two
optical fibre connectors work like a dual motorway, where one
connector transmits data to the RS485 port and the other
receives data from the RS485 port.
Mode single optical fibre connections
See Figure 3.
In this mode, two independent bi-directional optical fibre cables
are supported for use in a multi-drop formation. All data
received from optical fibrer port A is transmitted to both optical
fibre ports B and the local RS485 port. All data received from
the optical fibre port B is transmitted to both optical fibres port
A and the local RS485 port. In turn, all data received from the
local RS485 port is transmitted to both optical fibre ports.
Specifications
Operating temperature
Maximum relative humidity
Power supply
Current
Wavelength
Fibre size
Emitter type
Optical budget
Gain control
Rx sensitivity
Tx power:
Minimum
Typical
Maximum
Distance between two ATS1743
Number of units (cascading)
15 units in "Mode single optical fibre" and 14 units in "Mode dual
*
optical fibre" are tested and guaranteed. Cascading more units is
possible, but has not been tested.
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
2 / 16
0 to +50°C
95% noncondencing
12 V
60 mA
820 nm
62.5/125µm multimode
AlGaAs LED
15 dB typical
Fixed internally (non-adjustable)
−27 dBm typical
−21 to −15 dBm
−17 to −12 dBm
−14 to −10 dBm
To meet optical budget (15 dB)
15*
1999/5/EC (R&TTE directive): Hereby, UTC Fire &
Security declares that this device is in compliance with
the essential requirements and other relevant
provisions of Directive 1999/5/EC.
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.utcfssecurityproducts.eu
DA: Installationsvejledning
Beskrivelse
ATS1743 er en RS485 til multimode optisk fibre interface, for
direkte udvidelse af Advisor Master data bus med optiske
fibre.
Montering af enheden
ATS1743 har et standard ATS "BB" printformat, der kan
monteres i et ATS kabinet.
Figur 1: Tilslutninger COMMS
Figur 2: Ved dobbelt optiske fibertilslutninger
Figur 3: Ved enkelte optiske fibertilslutninger
(1) Tilslutninger COMMS
(3) Enkelt optisk fiber
(2) Dobbelt optisk fiber
(4) ATS 2000/3000/4000,
Tilslutninger COMMS
Se Figur 1.
+12 rød,
12 V DC / 0 V forsyning.
0V sort
Maksimalt 60 mA, når der overføres med høj effekt på
begge fibre samtidig.
D+ hvid,
RS485-databussens positive og negative datatilslutning.
D− grøn
Enheder kan være op til 1,5 km fra en RAS, en DGP eller
en centralenhed, dog afhængigt af hvilket kabel der
anvendes. WCAT52/54 anbefales. 2-par, parsnoet skærmet
datakabel.
LED's
Der overføres data på RS485.
RS485
Der overføres data på fiberoptisk kanal A.
A
Der overføres data på fiberoptisk kanal B.
B