BEFORE CALLING FOR SERVICE
Check the following list to be sure a service
call is really
necessary.
A quick reference
to this manual
may
help you avoid an unneeded
service
call
THE AIR CONDITIONER
WILL
NOT OPERATE
Check
if,.,
Then.,.
Wall plug disconnected.
Push plugfirmly into wall outlet
oose fuse blown or circuri breaker tripped.
Replace fuse withtime delay type or reset circuit breaker.
ODE selector is OFF position.
I Turn MODE selector tothe desired COOL setting.
__
_--Unitwas turned off and then on too quickly.
J Turn unit off and wait 3 minutes before restarting
ITEMP
Control set warmer than room temperature.
J Turn TEMP Control cklckwise to a cooler setting (higher number).
AIR FROM UNIT DOES NOT FEEL COLD ENOUGH.
Check if...
Then...
MODE selector in LOW COOL position,
i Turn selector to HIGH COOL position
TEMP Control set too warm (lowernumber),
t Turn TEMP Control clockwise to a cooler setting (higher number1.
Room temperature below 70°F (21°C).
Cooling may notOCCur u ntil room temperature rises above 70°F (21°C).
Temperatureseosiogtubetoechingevaporatorcoil,located
behind front grille.
I Straighten tube away from evaperator ooil.
THE AIR CONDITIONER COOLING, RUT ROOM IS TOO WARM - ICE FORMING ON COOLING COIL BEHIND FRONT GRILLE.
;heck
if,..
Then,..
Outdoor temperature below 70°F (21°C).
To defrost the coil, set selector to FAN position. Then, turn TEMP control
]
counterclockwise to a warmer setting (lower number).
Air filter may be dirty.
Clean filter. Refer to Maintenance sectbn of owners manual. To defrost,
set selector to FAN position.
TEMP Control set too cold for night-time cooling.
To defrostthecoil,set selectorto a FAN position._en, cottheMODE
controlat FAN posltio_ or "High Cool"withthe TEMPcontrolto a warmerposffion.
THEAIRCONDITIONER COOLING, BUTROOM ISTOOWARM.
Check
if..,
Oirly air filter - air restricted.
TEMP Control set too warm.
Front of unit isblocked by drapes, blinds,furniture,
etc. Air distribution is restricted.
Doors, windows, re(jisters, etc. open. Cold air escapes.
Unit recentlytumed on in hot room.
Then...
Cleanair filter,Referto Maintenance sectionof owner's manual.
TurnTEMPcontrol c leckwise to a coolersetting(higher n umber).
Clearblookag_
Close doors, windows,re_isters,etc,
Allowadditional t imoto removestored heatfrom wells, C eiling, f loor,andfurniture.
THE AIR CONDITIONER
TURNS
ON AND
OFF RAPIDLY.
Check
If...
Then.,.
[ Outside temperatureis extremely hot.
I Set MODE on HiGH speed to bring air pest cooling coils faster.
I
NOISE
WHEN
UNIT
IS COOLING.
Check
If,,.
Then...
Seundof fan hlttin_water - fromthe moisture removal s ,/stom,
This is normal when humidity is high. Close doors, windows, and registers.
Windew vibration - poor iostallation.
I Referto installation lestructions or check with installer.
I
WATER
DRIPPING
INSIDE
ROOM
WHEN
UNIT
IS COOLING.
Check
if,,.
Then,,.
I The air cendltioner is imprcperly installed.
I Tilt air conditioner sligh_ to the outside to allow water drainage. Refer to
1
installation instructions or check with installer,
j
WATER
DRIPPING
OUTSIDE
WHEN
UNIT
IS COOLING.
Check
if...
Then...
I The unitis rem°_ng largequantities °f meisture
I
fromhumidroom.
t This is normal dudngexsessivety humid days.
-13-