Follow the instructions below to attach the Sani-Con® 600 to the
RV coach.
AVISO
ATTENTION
CAUTION
ATENCIÓN
AVIS
DANGER
NOTICE
Read and understand the warnings listed in this docu-
!
!
!
!
ATTENTION
ATTENTION
ATTENTION
ment before you install, operate, or service this system. If
you do not obey these warnings there is a risk of property
loss, injury, or electrocution. Do not make any changes to
this unit as this could result in property damage, injury, or
electrocution.
Thetford Corporation accepts no responsibility or liability for
damage to equipment, injury, or death that may result from the
system's improper installation, service, or operation.
Thetford Corporation recommends that plumbing and electrical
work be performed by a licensed tradesperson. Local permit and
code compliance is required.

Contents

(1x) Sani-Con® Turbo 600 Assembly - with OT (over-tem-
perature) protected pump
(2x) Mounting Brackets
(1x) 3" Inlet Hose
(1x) Hose and Nozzle Assembly with nozzle caps
(1x) Switch Box Assembly
(1x) Fuse Holder
(1x) 35 AMP Fuse
(2x) Electrical Connectors
(1x) Owners & Installation Manual
(2x) Labels with serial #
Required Materials (Not Provided)
Plumbing and End Caps (if necessary)
Wiring
Mounting Hardware
Schedule 30, 40, 80, or DWV rated hard pipe fittings or
minimum 10 PSI flexible pipe rating for pressure side of
pump.
Questions?
If you have any questions or need assistance, please contact
Technical Support at 1-800-444-7210, available Monday through
Friday 8 a.m. to 6 p.m., Eastern Standard Time.
Sani-Con Model 600 - Permanent Storage Mount

Installation

General Guidelines
Gray water bypass can be achieved by plumbing the discharge
line in a manner that gravity can allow liquid to flow to the hose
with no upward plumbing.
All systems rely on gravity to move the liquid waste to the pump;
therefore, make sure that the pump inlet is mounted below the RV
holding tank.
Each assembly comes with two labels. One label should be
placed in the hose compartment; the other should be placed in the
Owner's Manual.
If black and gray tanks are heated, treat Sani-Con® Turbo
600 in same manner.
Duty Cycle: Intermittent, five minutes continuous operation;
20 minutes off.
It is important to plumb hose avoiding sharp angles or
bends during use or storage.
Placement of the hose connection MUST be serviceable by
the customer.
Warnings and Cautions
Read and understand the warnings and cautions listed in this
document before you install or operate this unit.
AVISO
CAUTION
AVIS
NOTICE
!
AVIS
NOTICE
AVISO
CAUTION
!
AVIS
NOTICE
AVISO
CAUTION
!
2
Do not make any changes to this unit, as this could result
in property damage or injury.
Gray and black water tanks MUST BE COMPLETELY
FREE FROM DEBRIS before installing and operating the
pump. Failure to comply with this warning could result in
a voided product warranty and equipment failure.
The installation site of the pump MUST be able to support
a minimum of 30 pounds.