Operation, cont'd.
PREPARE HOSE FOR STORAGE
Refer to Fig. 1 and Fig. 5.
1. Ensure pump is off.
K2
2. Drain hose (
) by holding at a sloped angle to direct excess
water into the dump station.
TIP For Faster Draining: Leave gray gate valve
NOTICE
open allowing hose to vent and expediting the process.
K2.2
3. Disconnect nozzle (
K2.3, K2.4
4. Install cap(s) (
5. Return hose to coach hose compartment (
connected to coach.
Helpful Hints
■
Additional hoses can be purchased from Thetford and used
to extend the length of the evacuation hose. Connect the
hoses using 1.5" (3.8 cm) barbed coupling with clamp.
■
If you wish to extend the evacuation hose, connect a .75"
(1.9 cm) inner diameter garden hose to the end of the
nozzle.
A longer evacuation hose reduces flow rate.
NOTICE
■
Before storing the hose, make sure that all liquid has drained from
the hose.
Gray water bypass is possible if the discharge plumb-
NOTICE
ing does not flow upward.
Inspect pump connection to the RV annually.
NOTICE
Obstruction Removal
Refer to Fig.1 and Fig. 5.
Be sure to have container available for capturing system
NOTICE
fluid!
1. Ensure all contents have been drained from system.
Turn off power and remove pump fuse. Once the obstruc-
AVISO
AVIS
NOTICE
ATTENTION
CAUTION
ATENCIÓN
DANGER
!
!
!
!
tion is removed, there is potential injury to hands or
ATTENTION
ATTENTION
ATTENTION
fingers in the path of the impeller if the power is on!
2. Disconnect the power by removing the pump fuse or discon-
necting the battery.
5B
3. Verify all gate valves (
Plumbing from the discharge port (
NOTICE
be disconnected.
Sani-Con Model 600 - Permanent Storage Mount
) from dump station.
).
5D
); leave hose
) are closed.
K1.1
) may need to
4. Locate 3" inlet hose
to the pump.
AVISO
AVIS
NOTICE
ATTENTION
CAUTION
ATENCIÓN
DANGER
!
!
!
!
ATTENTION
ATTENTION
ATTENTION
5. Remove the pump from the 3" inlet hose (
(5B)
6. Remove the obstruction.
7. Insert the pump inlet into 3" inlet hose
clamp.
8. Reconnect the power.
9. Operate system using gray water; check for leaks.
Winterizing the Sani-Con® Unit
Refer to Fig. 1 and Fig. 5.
1. Ensure all tanks are empty.
2. Pour RV antifreeze into the empty black water tank.
NOTICE
3. Turn on pump.
4. Run pump until the antifreeze begins to discharge from
universal nozzle (
5. Turn pump switch to the Off position.
6. Drain hose (
excess water; return hose to storage position.
8
(K7)
and loosen the hose clamp closest
Do NOT remove pump housing. Obstruction MUST be
removed through inlet.
K7
Be sure to have container available for capturing system
fluid!
K2.2
).
K2
) by holding at a sloped angle to remove
K7
).
) and tighten hose
www.thetford.com