G Two Sounder units in series
Note: In this configuration the total current consumption approaches 900mA. Ensure that
the alarm panel can source this amount of current. If in doubt change the mode of
operation of one or both units to SCB to reduce the current load on the panel.
G Tamper Switches (C)
Care should be taken to ensure that none of the wiring prevents any of the tamper
switches from moving freely.
G Battery Replacement
To change the battery, remove the PCB cover by unscrewing the four securing screws
and unscrew the battery terminals to release the battery leads. Installation is reverse of the
above. Always ensure battery leads are connected to correct polarity terminals.
Note: The strobe circuit can retain a stored charge for some time after the power to the circuit
has been removed. Care should be taken when handling the PCB.
G Weather Proofing
Please ensure that all reasonable precautions are taken to ensure unit remains dry during installation.