Pressure Transmitters
BSP-Bxxx-xx004-xxxxxA-xx, BSP-Vxxx-xx004-xxxxxA-xx
Type code for pressure transmitters
Physical unit
M = millibar
W = millibar, vacuum (from –1 bar)
B = bar
V = bar, vacuum (from –1 bar)
K = kilobar
Max. pressure range (value correlates with phys. unit)
001 = 1
010 = 10
100 = 100
999 = 999
Process connection and housing
D = external thread G1/4"
F = external thread NPT 1/4"
H = external thread G1/2"
K = external thread G1/4"
Seal/sealing system (see BHS code)
V = Viton sealing ring (ISO: FKM, DIN: FPM)
Housing type
004 = pressure transmitter
Interface to PLC
A = analog data
Output function/output technology
04 = 1 x 0...10 V (3 conductor)
06 = 1 x 4...20 mA (2 conductor)
Variant/options
A = Basic variant
Subversions based on main version
1 = Basic variant
Operating elements
A = no display, no buttons
Connector system
S4 = M12, 4-pin
Special characteristics or design (optional)
Z = General special design
T = Temperature-resistant
0 = Basic special design
www.balluff.com
BSP - V 002 - F V 004 - A 06 A 1 A - S4 - T
English
5