Advanced Settings

Heater Settings
Probes
Probe Application
Offset
Reset
12
These options can affect the performance of your thermostat and should only be modified by an experienced professional or under
the instruction of LATICRETE Technical Support
Heater Limits
Set the temperature limits for your floor type. User Defined lets you set custom limits
Regulator
Regulator mode controls the heating in 10 minute cycles. The number you enter is the number of minutes
in every 10 minute cycle that the heating will be on. This mode will not use the floor or air sensors for
measurement
Master/Relay
This allows one thermostat to control another
1.
2.
3.
4.
5.
Gradual Start
Set the maximum temperature and time required to reach that temperature
Set the specification of the probes. You can also choose to hide the error message if you do not want to connect a probe
Choose if the floor probe is being used as a Floor or Amb (ambient) sensor
Set the offset of the sensors to improve accuracy
This will restore all the factory default settings. You can also hold the button on the rear of the front module for 10 seconds to
perform a system reset
Choose which thermostat is Master and which is Relay
Use low voltage cable to connect terminal 6 of both thermostats
Use low voltage cable to connect terminal 7 of both thermostats (in addition to floor sensor cables
on the Master thermostat)
Set Relay thermostat to Relay mode first, then set the Master thermostat to Master mode
Program the Master thermostat. The Relay thermostat will no longer use its sensors, it will follow
the Master thermostat