Installation Instructions for Optional Fixture Mounts
Wiring the AC Beacon to the CMXC-SB
and PMXC-SB
The CMXC-SB is not suitable for use with through-branch circuit
conductors.
SHOCK HAZARD—To avoid electrical shock hazards, do not
connect the light to the supply circuit when power is applied.
SHOCK HAZARD—To reduce shock hazards during
maintenance POLARITY MUST BE OBSERVED when
connecting AC units to the power source.
See the figures on pages 6 and 7. To wire the AC beacon to the
fixture terminal block:
1. Connect the phase (hot) power source wire to the terminal
block screw marked L + .
2. Connect the common (neutral) power source wire to the
terminal block screw marked N-.
3. If required by local building codes, connect the earth ground
wire to the green screw in the fixture mount.
4. Place the terminal block in the fixture mount and secure it with
the mounting screws.
5. Plug unused conduit entries with the provided close-up plugs.
6. To prevent galling and ease future maintenance, ensure that the
threads on the fixture mount are clean and lubricated.
7. Thread the fixture clockwise into the fixture mount and hand
tighten it securely.
Models CMXC-SB, PMXC-SB, and WMXC Series
9