Hergom L-09 CA Instrucciones Para La Instalación, Uso Y Mantenimiento página 30

Cocina calefactora
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2.- INSTALLING DRAW REGULATION VALVE AND CLEANING COVER.
Although the closed cookers have been
provided with a system to regulate the
input
of
fresh
combustion, it is advisable, mainly for
installations with high draw systems of
over five metres, good construction,
insulation... to place a regulator/cover
on the wall, near the cooker output, to
help control chimney draw, heat power
and fuel consumption.
The said regulator/cover, given its
deign, will not only control the chimney
draw but also provide a window to
access
the
chimney
air
required
for
for
cleaning
purposes,
which
performance.
The
regulator/cover
installed
following
indicated in fig. 13.
The regulator MUST NOT totally close
off the passage of fumes, as an accident
may occur if they cannot be evacuated
completely.
The
open
safety
circulation of fumes must not be
less than 20% of the cast iron
frame gap. If necessary, cut the
regulator to provide the above-
mentioned
Fig.12
will
improve
its
can
be
easily
the
instructions
gap
for
the
gap.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

L-09 cc

Tabla de contenido