Samsung DV405 Información Técnica página 2

Ocultar thumbs Ver también para DV405:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
ERROR ITEMS AND DIAGNOSTIC CODES
An occurrence of an Error will make a sound of error melody for 5sec and continuously show one
of the Error Displays from the following errors.
Error Display
tE
HE
dE
dF
bE2
FE
2E
AE
Et
(Technical)DV405-02365H-03_EN_130221.indd 2
WARNING
Trigger
The Termistor resistance is
very low or high.
Invalid heating Temp in
running the dryer
Running the dryer with door
open
Invalid door state for more
than 256 milliseconds
Invalid state of key circuit
short for 30 secs
Invalid power source
Frequency
Electronic Control Problem
(Over Voltage Error)
Electronic Control Problem
(Communication Error)
Invalid state of Eeprom
communication
2
Action Taken
Check for:
- Clogged lint screen.
- Restricted vent system.
- Check Thermistor resistance.
Check for:
- Restricted vent system.
- Check Thermistor resistance.
Check for:
- Close the door, and run the dryer.
- Loose or open wire terminals in
Door Sense circuit.
Check for:
- Loose or open wire terminals in
Door Sense circuit.
Check for:
- Display PCB key circuit short or
not.
Check for:
- Not using regular power source
frequency
- Invalid power frequency sense
circuit
Check for:
- Check PCB and Wire harness.
- Check Power supply.
Check for:
- Check PCB and Wire harness.
- Replace PCB.
Check for :
- PCB with Eeprom circuit.
2013-02-21