WIRING EXAMPLES

The connection for a mute button or switch in the MIC/LINE 1 channel can be used by two devices at the same time for muting a music signal
or initiating the chime signal. To do so, the corresponding mute contacts of both devices must be connected to the contacts C and + of the
terminal block connection of the MIC/LINE 1 channel.
2
1
When wiring the terminal block, please ensure that the correct pin assignment is observed (see illustration below the terminal block
2
1
connections). The manufacturer assumes no liability for damage of any kind resulting from incorrect wiring! Further information on the
correct wiring of terminal blocks can be found under the item TERMINAL BLOCK CONNECTIONS in these instructions.