CAME MR8534 Manual Del Instalacion página 7

Detector de seguridad
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
4
SETTINGS
FACTORY VALUE
X
ORANGE
GREEN
OFF
5
CALIBRATION
RED-GREEN
OFF
GREEN
RED
4
ORANGE
5
6
DOOR SAFETY CHECK
IMPORTANT: Test the good
functioning of the installation
before leaving the premises.
If necessary, position spots
closer to or away from the door
and relaunch a calibration.
MOUNTING
SIDE
RELAY 1
ON
STOP
RELAY 2
OFF
REOPENING
LED during detection:
R1 > RED
R2 > GREEN
When the LED is off on all modules, the detection zone is OK.
The detection zone is too short:
turn the screw clockwise.
The detection zone is too long:
turn the screw anticlockwise.
Step out of the detection fi eld.
If necessary, change angle or switch off background (DIP 3 = OFF).
Launch a new calibration.
FREQUENCY
BACKGROUND
FREQ A
FREQ B
Set different
Not enough background
frequencies on
refl ectivity: switch to OFF
modules close to
each other.
* Recommended for most applications.
Moutning height > 3 m: set to LOW for
EN 16005 and DIN 18650-conformity.
After changing a DIP-switch, the orange LED fl ashes.
A LONG push on the push button of the MASTER
confi rms the settings of ALL MODULES.
Afterwards, a number of green fl ashes (x) indicates
the number of connected modules.
A SHORT push on the button of the MASTER launches a
calibration on ALL MODULES.
Do not stand in the detection fi eld!
UNCOVERED
ZONE
ON
HIGH*
OFF
LOW
Approximate values at 2 m:
high= 30 cm, low = 15 cm
The fl ashing speed of
the LED increases when
approaching the optimal
position.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mr8570Mr8590

Tabla de contenido