Pipe
Pipe Position
Size
+5.0 degrees tilt
+2.5 degrees tilt
0 degrees (no tilt)
1.66 in O.D.
-2.5 degrees tilt
-5.0 degrees tilt
+5.0 degrees tilt
+2.5 degrees tilt
2.38 in O.D.
0 degrees (no tilt)
-2.5 degrees tilt
-5.0 degrees tilt
FCC NOTICE
CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)
ELECTRICAL CONNECTIONS
STEP 1:
Make the following Electrical Connections to the terminal block:
a. For 120/277/347V connect the black fixture lead to the voltage
supply position of the terminal block (Hot 1 for 208/240/480V
wiring).
b. For 120/277/347V connect the white fixture lead to the neutral
supply position of the terminal block or (Hot 2 for 208/240/480V
wiring).
c. Connect the green or green/yellow ground lead to the green wire
position of the terminal block.
Dimming capabilities are accessible through the NEMA
when used with a photo control with dimming capabilities.
STEP 2:
Push excess supply wires into pole.
© 2019 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change.
See http://lighting.cree.com/warranty for warranty and specifications. Cree
Traveyo
is a trademark of Cree, Inc. NEMA
TM
2 of 2
TORQUE VALUES
Bolt Torque
Required (in-lbs)
200 +/-30
200 +/-30
200 +/-30
200 +/-30
200 +/-30
200 +/-30
200 +/-30
200 +/-30
200 +/-30
200 +/-30
receptacle
®
and the Cree Logo are registered trademarks, and
®
is a registered trademark of the National Electrical Manufacturers Association.
®
Bolt Torque
Required (N-m)
23 +/-3
23 +/-3
23 +/-3
23 +/-3
23 +/-3
23 +/-3
23 +/-3
23 +/-3
23 +/-3
23 +/-3
STEP 3:
Close cover, making sure that no wires are pinched and latches are
fully engaged.
OR HOT 1
NEUTRAL
OR HOT 2
NEMA
7-PIN PHOTOCELL RECEPTACLE
®
NOTE:
Dimming capabilities are accessible through the
NEMA
7-Pin receptacle when used with a photo control
®
with dimming capabilities.
STEP 1:
Rotational adjustment of the photo control is
STEP 2:
Engage/install photo control into NEMA receptacle on
top of the fixture. If no photo control will be used with
luminaire install customer supplied shorting plug into
receptacle.
STEP 3:
Firmly rotate photo-control with its photo-eye
approximately in the 'N' north direction. Some photo-
controls operate best somewhere between NW and NE.
TERMINAL
BLOCK
LINE
LINE-BLACK
GREEN
GROUND-GREEN
NEUTRAL-WHITE
tool-less.