LAMP COMPARTMENT DIMENSIONS Min.
5 inch (127mm) DIA X 5.5 inch (139.7 mm) H for 6-inch
This 6 inch retrofit downlight is designed to install in standard 5 and
6 inch cans.
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed including the following.
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
2.
WARNING – Risk of fire or electric shock. LED Retrofit Kit
installation requires knowledge of luminaires electrical systems.
If not qualified, do not attempt installation. Product must be
installed in accordance with NEC or your local electrical code. If
you are not familiar with these codes and requirements, contact
a qualified electrician.
3.
Suitable for damp locations. For indoor use only.
4.
Suitable for Type IC or NON-IC Luminaires.
5.
Do not make or alter any holes in a wiring enclosure or
electrical components during the kit installation.
6.
WARNING – Risk of fire or electric shock. Install this kit only
in the luminaires that have the construction features and
dimensions shown in the photographs and/or drawings.
7.
WARNING – To prevent wiring damage or abrasion, do not
expose wires to the edge of sheet metal or any other sharp
objects.
8.
WARNING: Not for emergency lighting.
9.
Maximum 8 of 12 AWG through branch circuit conductor suitable
for 75°C permitted in box
10. WARNING: RISK OF FIRE OR ELECTRICAL SHOCK. Do
not alter, relocate, or remove wiring, lampholders, power
supply, or any other electrical component.
11. WARNING - Risk of fire or electric shock. Install this kit
only in luminaires that have the construction features and
dimensions shown in the photographs and/or drawings and
where the input rating of the retrofit kit does not exceed the
input rating of the luminaire.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
Min 5"
(127mm)
models.
http://lighting.cree.com/warranty
Document:
LPN000244_B
Created By:
TMT
PACKAGING CONTENTS
•
6" retrofit downlight
•
Field applied label
•
Installation instructions in English, French, and Spanish.
INSTALLATION
1.
Make sure the POWER IS TURNED OFF at the source to the
recessed can.
2.
Remove existing trim and bulb revealing the existing recessed
sockets.
INCANDESCENT HOUSINGS
1.
Unscrew the wing nut inside the can to detach the socket bracket
from the can. Disengage the socket from the socket bracket. See
Figure 1.
2.
Thread the Socket Adapter into the socket. See Figure 2 on the
back page.
3.
Plug the female connector of the retrofit trim onto the male
connector of the socket adapter assembly. See Figure 3 on the
back page.
4.
If using torsion springs, squeeze both torsion spring arms together
and insert into the torsion spring slots (or c-clips) of the can. See
Figure 4 on the back page.
5.
Tuck all wires into the can and carefully push the retrofit trim
into can (Note: to provide enough room in shallow cans carefully
position SOCKET ADAPTER and SOCKET adjacent to the side of
the LED DRIVER prior to inserting the RETROFIT TRIM into the
CAN). See Figure 4 on the back page.
FIGURE 1
|
866.924.3645
Date