Cold climate installation recommendation: When installing this unit against a non-
insulated exterior wall or chase, it is mandatory that the outer walls be insulated to
conform to applicable insulation codes.
ELECTRICAL CONNECTION
A 15-Amp, 120-V, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fi replace will
be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation. The unit comes standard with 6-ft. three-wire
cord, exiting from the rear of the fi replace. Avoid using an extension cord. If an extension cord must be
used, it must be a minimum 14 AWG, three wire with grounding type plug connector and rated not less
than 1875 watts. The cord shall not be more than 20 ft. in length.
OPERATING INSTRUCTIONS
Control panel can be accessed at upper-right corner of insert (U).
- POWER
The power button supplies power to all of the functions of the fi replace. The power button will put the
insert in a standby mode. This will turn off all functions at once but will hold the settings in the memory.
By pressing the power button again the unit will turn on at the same settings.
NOTE: Holding the power button on the control panel for 10 seconds will disable the heater function.
- FLAME
Each time the fl ame button is pressed, the intensity of the fl ame decreases. There are 6 brightness levels
you can cycle through, including the OFF setting.
- HEATER
Your fi replace consists of a fan-forced wire-element-type heater. There are 11 thermostat levels you can
cycle through, including the OFF and ON settings.
This button on the remote control only turns ON and OFF heater function.
NOTE: To change between °F and °C press and hold the heater button on the control panel for
10 seconds.
- TIMER
Press the timer button to cycle through the 10 timer settings (30 minutes, 1 Hour, 2H, 3H, 4H, 5H, 6H,
7H, 8H and 9H) and the OFF setting.
Note: When a function is changed from the control
panel or remote control there will be a corresponding
indicator (see Figure 1) on the upper-right of the
projection screen. The indicator shows the function
changed and the level selected by the control panel or
remote control. When the function is turned off, the
corresponding indicator will fl ash 5 times and then
fade off.
11
°
C
°
F
Fig . 1