PROCEDURE
1
2
CONTACT ACTUA-
The tool fires a nail.
TION
FULL SEQUENTIAL
The tool fires a nail.
ACTUATION
In order to fire a second nail, you should
both release the Trigger and remove
the Contact arm from the surface.
DRIVING DEPTH ADJUSTMENT DIAL (Fig.10)
TA238B/18-6
Adjust the driving depth by twisting the adjustment dial 1 as in-
dicated below.
Deep
REMOVING JAMMED NAILS
WARNING
ALWAYS disconnect the air supply.
Wear gloves when removing jams; do not use bare
hands.
Confirm that you have removed all staples from nose of
tool before reconnecting to air supply.
TA116A/22-9, TA116A/21-13 (Fig.11)
1
Disconnect the air supply.
2
Remove the set of staples from the Magazine 1.
3
Take out the 4 hexagon socket head cap screws from the
Magazine and remove the Driver Guide 2.
4
Clear the staples jammed inside the Driver Guide using a
thin iron bar or a flat-blade screwdriver.
5
Reinstall the Driver Guide, reinsert the set of staples and
bring back the Slider Unit 3.
TA238B/18-6 (Fig.12)
1
Disconnect the air hose.
2
Remove the set of staples from the Magazine 1.
3
Take out 4 hexagon socket head cap screws from the Mag-
azine.
4
Clear the staples-jammed inside the Driver Guide 2 using
a thin iron bar or a flat-blade screw driver.
5
Reinstall the Driver Guide and the Front Cover 3 the set of
staples and bring back the Slider Unit 4.
CONTACT TIP
TA238B/18-6 (Fig.13)
Attach the Contact Tip 1 on the tip of Contact Arm 2, when driv-
ing nails to a soft material.
Depressing the Contact Arm.
Pulling the Trigger and keeping it
pulled.
Shallow