3. Technical data
Supply voltage
See device
Contact material (115V / 230V)
AgSnO
2
Contact material (12V / 24V)
AgNi
Type of protection
IP 20 to DIN EN 60529
Permitted ambiet temperature
-30°...+55°
Mode of oeration
1 BSTU
Degree of contamination
2
Rated surge voltage
4 kV
Standard
DIN EN 60730-1/DIN EN 60730-2-7
CFL, LED
Ideal for modern lamps
7. Menu overview
9. New Program
OK
OK
OK
OK
OK
OK
**At 2 channel
version
Automatic Mode
10. Key function
1. To access the Enter-mode (program, adjustments, options) from the au tomatic-mode.
2. To revert to the beginning of the current (sub -) menu.
1. To adjust the flashing digit.
2. To scroll through a choice
1. Automatic-mode: To switch the channel ON or OFF until the next programming step occurs.
2. Automatic-mode: A push longer than 3 se c. = Permanent switching status.
/
1. To activate the time switch when operated without power supply.
2. To confirm the selection or the entered data.
13. Additional adjustments
Menu
Main menu Application
Program query
Program
To query the programming steps and remaining memory locations
Deletion of switching time(s). The program for all chan nels, single
Program delete
Program
channels and single programming steps within on channel ca n be
deleted.
Date-Time
Adjustment
Adjustment of date and time
Summertime
Adjustment
Adjustment of the daylight saving time mode (ON/OFF)
Language
Adjustment
Choice of languages

Factory Defaults

Adjustment
Reset to the state of delivery.
Displays the hour counter and pulse counter for each ch annel and
Counter
Options
the time switch itself.
The time switch can be locked with a 4-digit PIN-Code. The code
PIN-Code
Options
can be adjusted, activated and deactiva ted. If you have forgotten
the Code please call customer service.
Extra switching time:
Program -> new program -> channel A/B -> Extra switching time -> ...
These programming steps are single switching times by date.
TS-DW-2-NFC 93152 und TS-DW-3-NFC 93153
Connection diagram
4. Service
Brück Electronic GmbH
Gerberstr. 33, D-51789 Lindlar
Telefon: +49 (0) 2266.90 121-0
Fax: +49 (0) 2266.90 121-50
E-Mail: info@beg.de
Internet: beg-luxomat.com
OK
OK
OK
erm
1. Safety instructions
The installation and assembly of electrical
!
equipment must be only carried out only by a
skilled Person! Otherwise fire danger or danger of
an electric shock exists!
Connect the supply voltage/frequency as stated on
!
the product label!
Warranty void if housing opened by unauthorised
!
person!
The electronic circuit is protected against a wide
!
range of external influences. Incorrect operating
may occur if external influences exceed certain
limits!
5. Intended use
The device fits for the particular use of the following tasks: Illumination
of private and industrial areas, street and shop-window lightening,
regulation of air conditioning, flushing, motors, pumps, plants and
machinery as well as to simulate presence etc.
Operate the device in a dry room only! The installation must be in
accordance with the instruction manual. The device is not qualified for
security relevant tasks such as emergency doors, fire protection
equipment
8. Symbol legend
Channel is switched ON
Channel is switched OFF
For the current date the "holiday program" / "permanent by date" is a ctivated
erm
Standard programming step
Current state is based on a manual over -ride. The state will be cancelled with the next programming step.
Current state is based on a manual over-ride. The state is permanent until terminate d manuall.
erm
Days of the week Monday, Tuesday, .. . Sunday;
The underscores indicate if the program is act ive for the days above.
I
Current state is based on a switching time with pulse function
The time switch is locked; to unlock the device the PIN has to be e ntered.
OK
OK
OK
OK
OK
OK
OK
OK
OK
11. 12. Permanent / Extra switching times
Permanent On / Off
Extra switching times
optionally selectable
14. Pulse
Program -> New program -> Channel A/B -> ...
The pulse function provides you the opportunity of programming a switching time with a defined duration.
As soon as the pulse-duration has expired the time switch switches OFF automatically (the duration of the pulse is up to 59:59 mm:ss).
The programming is carried out like a standard switching time (see point 8 / 9) with following differences
Pulse
Choose
function (9F).
pulstime minute
Define the duration of the pulse (
Program the days of the week
time hour
Program the switching time (
Validation: Confirm the blinking summary of the pulse program
15. Programming via NFC (1)
2. Initial operation
The time switch is delivered in sleep-mode, the display is switched
off.
Press
-/
button to wake it up.
The current date and time is already programmed and Europea n
daylight savings time is activated.
Select the desired language by pressing
by pressing
. (Remark: By pressing
backwards from the current position)
If required, date, time and daylight savings time mode can b e
adjusted also by pressing
with
.
OK
OK
OK
OK
OK
OK
12. Cycle / Random (1)
Cycle
optionally selectable
h:mm:ss on-time (0:00:01 ... 9:59:59)
h:mm:ss off-time (0:00:01 ... 9:59:59)
Random
optionally selectable
no
yes
pulstime second
/
).
time minute
/
)
16. Notes on battery disposal
This device contains a long-term lithium battery. In connection with
the delivery of equipment containing batteries, we are obliged to
advise you of the following:You are required by law to return used
equipment and batteries as an end user. The return is free of charge.
EN
-buttons and confirm it
you move one step
-buttons and a subsequent confirmat ion
6. Battery
OK
OK
OK
OK
OK
OK
Z

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Chronolux ts-dw-3-nfc 93153

Tabla de contenido