4

Basic principles of addressing

Electronics (left)
Inputs
Outputs

! !
8
0
20
1
9
2
21
3
10
4
22
5
11
6
23
7

Input module
4 inputs
Input module
8 inputs
!
Output module 4 outputs
1. Method of counting valves from the node to the right.
(lower value address = pilot solenoid 14;
higher value address = pilot solenoid 12).
2. Method of counting electric outputs from the node to the left
and from top to bottom.
3. Method of counting electric inputs from the node to the left
and from top to bottom. Observe status bits.
Detailed instructions on addressing the valve terminal can be
found in the "Electronics manual."
9909 NH
Node
Pneumatics (right)
Outputs
" #
0 1
2
4
3
5
7
16
17
18
19
"
Single solenoid manifold
#
Double solenoid manifold
$
Round up
# #
$
6
8
10
12
14
9
11 13 15