ENGLISH
5.3.3
Connection LP compressor-HP compressor
To connect the LP NITROX compressor to a high pressure compressor :
- connect, with a hose (a), the mixer pipe outlet (b) to the intake (c) of the
high pressure compressor;
- fix the hose to the fittings using hose clips.
IMPORTANT: Use the hose supplied with the compressor.
Never use a hose with a cross-section smaller than the one on
the supplied hose.
LP-300
5.3.4
Connecting the PRO O2 Oxygen analyser
The PRO O2 Oxygen analyser (a) must be connected with the fittings for
connection of refill hoses (b) of the HP compressors.
Check that there is always a flow regulator (c) between the analyser (a) and
the fittings for connection of the refill hoses (b).
MU-LP300-600-1018
b
a
c
ESPAÑOL
5.3.3
Conexión del compresor LP - compresor HP
Para conectar el compresor LP NITROX a un compresor de alta presión:
- conecte con un tubo (a) la salida del tubo de mezcla (b) a la aspiración (c)
del compresor de alta presión;
- fije el tubo a los empalmes con abrazaderas.
AVISO: Utilice el tubo suministrado con el compresor.
No use nunca un tubo con sección inferior a la sección del
suministrado.
LP-600
b
5.3.4
Conexión al analizador de Oxígeno PRO O2
El analizador de Oxígeno PRO O2 (a) debe ser conectado con los empalmes
para la conexión de los látigos de recarga (b) de los compresores HP.
Compruebe que entre el analizador (a) y los empalmes para la conexión de
los látigos de recarga (b) exista siempre un regulador de flujo (c).
b
b
LP-300-600 NITROX
c
a
35 - 76