Installation
Electrical Plug Connection
Three-Wire Plug
NOTE: The power cord (pigtail) is NOT supplied with the electric
dryer. Type of pigtail and gauge of wire must conform to local
codes and instructions.
The method of wiring the dryer is optional and subject to local
code requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use COPPER WIRE only.
Shorter than 15
(4.5 m) use 10 A.W.G.
k
Longer than 15
(4.5 m) use 8 A.W.G.
k
1
3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(See NOTE above)
2
30 Ampere Fuses or Circuit Breaker
3
Neutral Wire
1. Remove access cover from rear of dryer.
Figure 27
22
A typical
INTERMEDIATE
30-Amp
FUSE BOX (May
Three-wire
be omitted if
Receptacle
service entrance
NEMA Type
box is fused)
10-30R
WALL RECEPTACLE
120 ± 12
V.A.C.
'
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
POWER SUPPLY
L1
L2
PIGTAIL CONNECTION
4
Metallic or Non-Metallic Sheathed Cable
(Copper wire only)
5
Pigtail to Dryer (See NOTE above)
6
Neutral
7
Terminal Block in Dryer
Figure 26
2. Use a strain relief and insert end of power cord
through power supply hole.
D695I
POWER SUPPLY
1
2
3
INTERMEDIATE
SHUT-OFF BOX
(May or may
not be fused)
4
5
6
7
L1
L2
DIRECT CONNECTION
Figure 28