It switches on service light for 90 seconds
It cancels control START during opening (residential system)
3
It sets automatic shutting of gates with time adjustable by trimmer
4
BREAK
SW2
1
Take off during starting not working
2
Extra pressure (inversion) of 2 sec. during starting
Adjusting of trimmers: BREAK Breaking time – DELAY Delay between the leaves - WORK Working time
BREAK
It counts the time of break
after opening and before
closing.
Adjusting of electric clutch POWER
Any adjust of electric clutch must be made from qualified people in order to avoid any possible accident and reduce all crashing
risks.
Check that leaves on movement can be stopped at any time easily.
Power measurements on leaves have to be made following to actual norms.
Check periodically the clutch system in order to guarantee full safety.
5.
Terminals descriptions
Join with a bridge the N.C. (normally closed) entrances you don't used
If you are using more contacts N.C. on same entrance, they must be connected in set.
If you are using more contacts N.O. on same entrance, they must be connected in parallel
1
Entrances 1 and 2 for power supply 230 Vac 50
2
Hz
Entrances for flashing light 220 Vac max. 100
3
Watt
4
5
Entrance motor 1 delayed during opening max
6
500 Watt 6 common – 5 close – 7 open
7
Capacitor connects to 5-7
8
Entrance motor 2 (pedestrian) delayed during
9
closing max 500 Watt 9 common – 8 close – 10
10
open Capacitor connects to 8-10
Exit 12 Vac for electric look with max 15 Watt
11
(extra pressure must be activated by dip SW2 -2
12
ON)
13
Entrance START. If set during opening it stops
15
the movement; if set during closing invert the
movement. Contact N.O.
13
Entrance STOP. If set it stops any movement and
16
cancel the automatic shutting. Contact N.C.
6.
Testing
To be made with leaves of gate in the middle position and only after installing the safety devices required from actual rules in
order to reduce any risk.
Check all motor connections remembering that first operation made by the control panel is an opening.
Check that motor 2 is the first one starting otherwise invert the wires of 2 motors. (entrances 5-6-7 with 8-9-10)
Be sure that motor 2 starts opening otherwise invert the wires on entrances 8-10
Be sure that motor 1 starts opening otherwise invert the wires on entrances 5-7
Make the completely opening and adjust the limit switches
Make the closing and adjust the delay between the leaves
Check that pushing power follows the actual norms adjusting it by electronic clutch
Check that all safety devices installed are working properly in order to reduce any risk.
All people in charge of the automation must be trained about the safety devices, controls and dangerousness of system
Fill up technical booklet and carry out the obligations required from actual rules and norms
E
1.
Normas de seguridad generales
ATENCIÓN: Está prohibido efectuar mantenimiento o reparaciones de las instrumentaciones por parte de personal sin califica y en el
caso no hayan sido tomadas todas las precauciones para evitar accidentes: alimentación eléctrica desconectada (incluidas posibles
baterias de emergencia).
ATENCIÓN: Con cualquiera utilización no prevista por este manual de instrucciones y/o con cada modificaciones arbitraria del
producto o de sus componentes, DASPI queda exonerada de toda responsabilidad por daños o lesiones a cosas, personas o
animales.
ON
DELAY
Adjusting of the delay between the leaves: in closing
motor 2 delays from 2 up to 15 sec.
In opening motor 1 is always delayed 2 seconds
For working with led "gate open"
Control START always active. if set during opening it stops
the operator
Automatic shutting not working.
Take off during starting working
Extra pressure (inversion) of 2 sec. not working
It counts the working time either in opening and
closing. Time must be always adjusted 2-3
seconds more than real movement time of gate
13
Entrance pedestrian system. It opens just motor 2. If
17
working with just one motor it opens 2 or 15 sec. adjustable
by trimmer DELAY
Entrance of photocells. With 2 motors if photocells are
18
working also in opening they stop and re-start opening.
22
During closing they stop and invert.
With 1 motor, entrance can be used as safety device
system. During opening it stops and invert of 10 cm.
C
C
19
Entrance for photocells working during closing. They stop
22
and re-open.
Contact N.C.
20
Entrance limit switch open of motor 2 if working with 2
22
motors or limit switch open when working with 1 motor.
Contact N.C.
Entrance limit switch open of motor 1 if working with 2
21
motors or limit switch close when working with 1 motor.
22
Contact N.C.
Exit 24 Vac for external devices as well as extra photocells
23
24
25
Entrance for antenna: 26 hot pole – 25 copper cable
26
27
Exit for service light or led "open gate"
28
Contact N.O.