Hot Water Sizing Method For Mixing Valve Selection

1. Determine Fixture Units – Table 2
2. Using Total Fixture Units determine load in Gpm from Table 3.
3. Select product based on minimum flow requirement and allowable pressure drop (20 Psi).
Fixture Units
Fixture
Private
Lavatory
1
Kitchen Sink
2
Bathtub
2
Separate Shower
2
Clothes Washer
2
Dish Washer
1
EXAMPLE: A system with 40 Lavatory (Private), 40 Bathtubs (private) and 5 Lavatory (public) has total fixture count of 130
fixture units. From Table 3 - 130 fixture unit = 38 Gpm
Fixture Units
2
2
6
4.5
10
6.5
14
8.5
20
11
24
13
30
15
34
16.5
40
18.5
45
20
50
21
Min Flow
Product
GPM
MX127LF
1
MX128LF
2.5
MX129LF
3.5
MX130LF
5
MX131LF
8
MX132LF
12
This sizing method is a general guideline. Please refer to local building and plumbing codes for additional guidance.
Table 2. Fixture Unit Worksheet.
Public
# of Fixtures
2
4
4
4
4
2
Table 3. Domestic Hot Water Demand – Load Data.
Gpm
Fixture Units
55
60
70
80
90
100
130
160
200
260
300
Table 4. Single High Capacity MX Series Mixing Valve Selection Chart
Outlet Size
Inch
5
1"
9
1¼"
21
1½"
30
2"
40
2½"
76
3"
112
MX SERIES COMMERCIAL MIXING VALVES
Fixture Unit Calculation
(multiply by)
Fixture Units
x
x
x
x
x
x
Gpm
23
24
27
29
31
33
38
43
49
58
64
System Differential Pressure Drop (PSI)
10
15
13
15
29
36
43
52
57
70
108
132
158
194
5
Equals
Total
=
=
=
=
=
=
Total
Fixture Units
350
72
400
78
450
86
500
93
550
100
600
107
650
115
700
122
750
130
800
134.5
1000
156
20
25
18
20
42
47
60
68
80
90
152
170
224
250
Gpm
30
22
51
74
99
186
274
38-00034EFS—03