• Press [Test Mode].
• Touch the buttons [+] or [-] to increase or decrease the power (from 00 = minimum to 100 =
maximum)
The set power is stored instantly.
Press [
] to return to the [
System diagnostics
The values of the sensors and actuators in the boiler are available.
Note: To return to the Service Menu, touch the arrow at the top left of the screen
Description
Combustion
Burner power
Flame status
Fan rpm
Operating hours
Fume Temperature
Hydraulics
Heating Flow
Heating Return
NTC DHW sensor (°C)
DHW draw-off
Modulating pump speed
System water pressure
Environment
External probe
Menu [Transparent parameters B]
By selecting a parameter on the screen, the possible values will be shown. If the values
A
shown do not match those indicated in the corresponding "Range" column, check that the
parameter B01 is correctly set to RRT.
Code Description
B01 Boiler type selection
B02 Exchanger type
Absolute Maximum Heat-
B03
ing Power
System water pressure
B04
protection selection
B05 NOT IMPLEMENTED
190
Service Menu] or [
Range
00% = Minimum
100% = Maximum
00 ÷ 255
00 ÷ 12000
00 ÷ 99999
0 ÷ 125 °C
0 ÷ 125 °C
0 ÷ 125 °C
0 ÷ 125 °C
0.0 ÷ 99.9 L/min
00 ÷ 100%
00 ÷ 9.9 bar with pressure transducer
-30 ÷ +70°C
Range
RRP (INSTANTANEOUS COMBI)
RRH (HEATING ONLY also with OPTIONAL HOT WATER
STORAGE TANK
RRT (COMBI HEATING ONLY)
RRK (HEATING ONLY with HOT WATER STORAGE
TANK)
1 ÷ 4
0 ÷ 100% (Do not modify the value)
Pressure switch
Pressure Transducer
cod. 3541V280 - Rev. 00 - 03/2021
] to return to the main screen.
Default
RRT
RAGGIO 28 C =
RAGGIO 34 C =
RAGGIO 28 C = 85%
RAGGIO 34 C = 85%
Pressure transducer
--
RAGGIO C
2
3
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido