Work Pro DCA 1 Instrucciones De Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
5.1 INTERF. MODE
RS232
With RS232, DCA 1 accepts ASCII control commands from an external command console. See the control commands
compatible with DCA 1 in the ANNEX I.
5.1 INTERF. MODE
RS485
With RS485, DCA 1 accepts control commands from an external command console. See the control commands
compatible with DCA 1 in the ANNEX I. The control commands are the same as RS232 but with different interface.
5.1 INTERF. MODE
DMX - 001
DCA 1 needs four DMX channels for control purpose. In the display it is possible to select the first control channel
(between 001 to 509).
The channel occupation is as follows:
Channel 1: It control the OUTPUT 1 gain control ( in percentage from 0 to 100%)
Channel 2: It control the OUTPUT 2 gain control ( in percentage from 0 to 100%)
Channel 3: It allows to select the audio source in OUTPUT 1 with these values:
From 0 to 49: None
From 125 to 149: Input 4
From 225 to 255: Input 8
Channel 4: Same function and behaviour as Channel 3 but applied to OUTPUT 2
6. SECURITY
6.- SECURITY
PUSH TO ENTER
Push the encoder to create a password to avoid unwanted manipulations in the device.
6.- SECURITY
PASS: 000
Move the encoder and push to select each value until to create a password with 3 digits.
NOTE: Please, retain the password, it is not resetable
Turn the encoder clockwise to pass to next sub-menu
From 50 to 74: Input 1
From 150 to 174: Input 5
7
From 75 to 100: Input 2
From 175 to 199: Input 6
User Manual/Manual de Uso
From 101 to 124: Input 3
From 200 to 224: Input 7
DCA 1

Publicidad

Tabla de contenido
loading

Tabla de contenido