5.4

Time mode

• If the main display shows °C or °F, press MODE to select
TIME MODE. The main display shows ‚t' in TIME MODE.
• Press UP or DOWN to adjust the time in steps of 0.1 minute.
• Press POWER to select the power level. Use the guidelines in
section 5.8 to determine the correct power setting.
• Press START/STOP to start the heater. The main display shows
the time that remains.
• When the time has elapsed, the heater demagnetises the
workpiece, switches off, and generates an acoustic signal for
10 seconds.
• Press START/STOP to cancel the acoustic signal and stop the
heater.
• Remove the workpiece with proper handling equipment.
• The IH 070/090 is now ready to heat another workpiece
with the same settings.
5.5

Temperature measurement

When the heater is not operating, the temperature of the workpiece can be
measured by pressing MODE and START/STOP at the same time. The LED
on the START/STOP button flashes during temperature measurement. Press
START/STOP to cancel temperature measurement.
5.6

Change of temperature unit

Press MODE and UP at the same time to switch between °C and °F. The tem-
perature unit setting remains the same even after disconnection from mains
power.
5.7

Demagnetisation

The workpiece is automatically demagnetised when heating is complete.
Demagnetisation will not occur if the power is interrupted or the main switch
is switched off. To use the IH 070/090 for demagnetisation only, select TIME
MODE and set the time to 0.1 minute (6 seconds).
32
Induction Heater IH 070/090
© simatec ag