4. Installing the Side Faucet: NOTE: If there is not already a hole to
accommodate the side faucet, drill one 22 mm (.87") in diameter
through the sink deck.
a. Unscrew the nut at the base of the spout. Remove the nut and both the
steel and the rubber washers.
b. Insert the base of the spout through the hole in the sink deck, holding
it centered in the hole with the lights on the Data Collar facing the front
of the sink, replace the Rubber Washer (top) and the Steel Washer and
tightening the Brass Retaining Nut from underneath the sink.
5. Water Supply Connections:
NOTE: The orientation of the valve is only for reference. It may vary according
to your plumbing installation.
a. Disconnect the cold water supply line from the bottom of the existing
faucet. And thread the collar of the 3-way-diverter onto the faucet's Cold
Water Inlet.
10
Line to your exisiting faucet
(Cold Water Inlet)
b. Thread your existing cold water supply line that comes from the valve
on the wall into the side inlet of the 3-way-diverter
c. Thread the Braided Source Water Tube (supplied with the side faucet)
onto the bottom of the 3-way-diverter.
Braided water source tube
d. Remove the washer that is attached to the
smaller end of the Braided Source Water Tube
and place it in the small end of the tube, then
thread the small end of the tube onto the
Source Water Inlet of the Side Faucet