Discharge Pipe - VITO PRO-POWER VICO7.5 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

eN
operATIoN
pressure
Switch (Auto / Off) In the AUTO
position, the compressor turns off
automatically when the pressure
in the tank reaches the preset
maximum pressure. In the OFF
position, the compressor does
not work. The switch must be in
OFF position when connecting or
disconnecting the cable Power tools
or change in use.
pressure reGuLATor
The regulator controls the pressure
of air delivered through the hose
outlet.
sAFeTY VALVe
This valve automatically releases
air from the tank when the tank
pressure exceeds the preset
maximum pressure.

DIsCHArGe pIpe

This tube leads the compressed
air pump until the valve is
unidirectional. Avoid touching the
discharge tube during operation
of the compressor due to the high
temperature.
oNe-WAY VALVe
Allows entry of compressed air in
the tank and prevents it will return
pump.
peGA
Designed to move the compressor.
Never use the handle
WArNING:
to lift the compressor from the floor.
DrAIN
It lies at the bottom of the tank.
Daily is used to drain the moisture
accumulated in the bottom of
the tank (reducing the risk of
corrosion). Reduce the pressure to
0.7 bar before draining the tank.
LuBrICATIoN
This compressor is an oil-free
equipment and does not require
lubrication to function.
INITIAL perIoD
oF operATIoN
Do not place the
ImporTANT:
compressor without reading the
instructions.
1. Fully open the air flow by turning
the regulator clockwise.
2. Slide the switch in the off
position and turn on the power cord.
3. After connecting the compressor
(button switch in AUTO position),
let it work for 30 minutes to
make the running of the pump
components.
4. Turn the regulator knob
counter-clockwise. The air will
be accumulated in the tank until
the preset maximum pressure is
reached, at which the compressor
will be shut down. Figure legend:
AUTO or ON (upward) OFF
(downwards) On / Off switch -
button On / off Pressure switch
- switch
5. Turn the regulator knob clockwise
to allow air outlet accumulated. The
compressor will restart when preset
pressure is reached.
6. Close the air regulator by turning
the knob counter-clockwise. Turn
the pressure switch in the Off
position.
7. Push a valve or a tool to the free
end.
opeN THe THroTTLe
(AUTO - the compressor starts
and the air builds up in the tank;
Off position - the compressor does
not work). Make sure that the
button is in the OFF position when
connecting or disconnecting the
power cord from the compressor.
moIsTure
IN CompresseD AIr
The moisture contained in the air
tends to form droplets due to their
origin pump compressor. When
the humidity is high or when the
compressor is used continuously
for a long period of time, moisture
will accumulate in the tank. When
using a spray gun or pistol or sand
blasting, the accumulated water
will leave mixed with the substance
to be sprayed. Important: The
condensation will cause the paint
stains, especially when spraying
paints which are not water-based.
During blasting, the sand grains
tend to cluster and block the spray.
An in-line air filter located closest to
the gun help eliminate moisture.
19

Publicidad

Tabla de contenido
loading

Tabla de contenido