TECHNICAL SPECIFICATIONS
Rated voltage
Voltage range
Rated frequency
Voltage circuit self-consumption
Current circuit self-consumption
Instantaneous electrical magnitudes
Recording of maximums (via Modbus)
Monthly closures (via Modbus)
Load curve (via Modbus)
Tariff configuration (via Modbus)
Relay control (via Modbus)
Assigned current or base current
Maximum current
Operating current
Minimum start-up current
Precision
Measurement category
Constant
Meter operation
Optical pulse output
Electrical pulse output
Display
Memory back-up
Backup battery
Clock precision
Summer/winter time changeover
Protection class
Insulation
Casing protection type
Operating temperature
Storage and transport temperature
Relative humidity
Assigned contamination degree
Measurement circuit connections
External conductor terminals
Maximum screw tightening torque
Securing
Casing (Dimension)
DIMENSIONS
162
The PC applications for reading and configuring the CONTAX D-BUS series,
CONTAX ANRET and CONTAX D-BUS, are available from our Website, together
with the MODBUS SERIE CONTAX D-BUS REGISTER TABLE document for
advanced use of the MODBUS functions and registers.
3 x 230 /400 V~
-20% to +15% at rated voltage
50 Hz
< 1 W
< 0.1 W per phase
Phase voltages
Phase currents
Active, reactive, apparent powers
Power factor (cos )
Frequency
Angle between phases
Voltage, current, active/reactive power
Voltage drop
Up to 12 months
Total or separate in up to 4 rates
Active power, import, export
Reactive power, import, export
Integration period: 5, 15, 30, 60 minutes
Depth: 9000 registers (1, 3, 6, 12 months)
Active and reactive powers (import, export)
Up to 6 daily periods with 4 possible tariffs
Distinguish
between
Mo-Tu,
Saturday,
Sunday, Holidays.
Winter season, summer season
Status change
Reset by time, button, Modbus command
Over-current value (up to 90A)
Ib = 10 A
Imax = 65 A
from 500 mA to 65 A
40 mA (with power factor 1)
Class 1 according to EN 62053-21
Class 2 according to EN 62053-23
CAT III according to EN 61010-1
800 pulses/ kWh (optical and electrical
outputs)
800 pulses/ kvarh (optical and electrical
outputs)
Static (electronic measurement element)
Flashing LED with constant 800 pulses /
kWh. / kvarh
Opto-coupler
pulses
according
62053-31. Constant 800 pulses/ kWh /
kvarh
Six-digit digital (kWh/kvarh)
EEPROM
Lithium: 10 years at +20°C
±1.2 s/day
Automatic
II under correct installation conditions
Reinforced
between
all
terminals
accessible casing parts
IP 51 on front panel, IP 20 on the rest of the
casing, according to EN 60529
-25 ºC to + 55 ºC
-25 ºC to + 70 ºC
Annual mean < 75 %
Peak values 95 %
3 according to EN 61010-1
Direct by screwed terminals
2
(1-3-4-6-7-9-11)
4 mm
- 35 mm
2
(20-21-22-23-24-25) 0.5 mm
- 2.5 mm
0.8 Nm
Symmetrical 35 mm profile (DIN Rail).
According to EN 60715
nine DIN width modules
75.5
70.5
SCREEN DISPLAY EXAMPLE
Counter number (001)
Date (30/08/2012)
Total import
active energy (7803 kWh)
L1 Phase voltage (230,5 V)
L3 Phase voltage (230,5 V)
L2-L3 Phase voltage (399,2 V)
to
EN
L1 Phase current (9,998 A)
L3 Phase current (10,02 A)
and
L2 Phase active power (2,300 kW)
2
2
Total active power (6,910 kW)
L2 Phase reactive power (1,900 kvar)
Total reactive power (5,709 kvar)
Frecuency (50,01 Hz)
04/09.2015
Measurement constant (800 imp/kWh)
Time (11:59:30)
Total import
reactive energy (1607 kvarh)
L2 Phase voltage (230,5 V)
L1-L2 Phase voltage (399,2 V)
L3-L1 Phase voltage (399,2 V)
L2 Phase current (10,03 A)
L1 Phase active power (2,309 kW)
L3 Phase active power (2,301 kW)
L1 Phase reactive power (1,907 kvar)
L3 Phase reactive power (1,901 kvar)
Power factor (0,999 inductivo)
Baudrate (9600 bps)
Communication format (none, 8, 1)
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Telf.:+ 34 91 5672277; Fax:+34 91 5714006
E-mail:
info@orbis.es
http://www.orbis.es
A016.70.56605
E–28020 MADRID